The most effective method of searching for problems on
motherboard laptops is the method of measuring Voltage (Voltage),
Current (Current), signal (frequency). Inside the schema the
motherboard manufacturer has provided the Voltage Rail detail (the
voltage voltage that should be there) for the motherboard to
function properly. The task of the technician is to find out if there is
an above measuring subject missing (missing voltage and signal ).
Requirements for
motherboard life
require voltage 19V,
5V and 3V_ALW.
The measurement
point indicates that
19V is present with
the arrival of 19V
from VIN to + B
with source battery fet point, VIN for Charger IC and DC / DC IC.
Also ensure Upper N chanel source for 3V and 5V is present 19V
so it is ready at Triger by dc / dc ic and pass the 3V and 5V
voltages. The 3V and 5V measurements already present can be
measured on Inductor 3V and 5V respectively.
Measurements 3V and 5V at other point not mean 3V and 5V_ALW
are already present. VREG3 and VREG5 are not meant to mean
3V and 5V as requirements for life are available. Similar to facing
Short Motherboards, we only find the new availability short 19V, 5V
and 3V checked. How to quickly find short it must use a PSU, This
can save a lot of time in the search for short components. It is
important to know that before doing voltage inject or enter the
voltage we must know the direction of voltage and signal, voltage
line and most importantly is the voltage magnitude. As mentioned
above there is 19V, 5V And 3V on circuit power (VALW). An
injection error / insert voltage can be fatal to a componen2 which
has a maximal capacity under the voltage supplied. Unfortunately
again if the error enter / As described above there is a path 19V, 5V
and 3V on circuit power (VALW). An injection error / insert voltage
can be fatal to a componen2 which has a maximal capacity under
the voltage supplied. Unfortunately again if the error enter / As
described above there is a path 19V, 5V and 3V on circuit power
(VALW). An injection error / insert voltage can be fatal to a
componen2 which has a maximal capacity under the voltage
supplied. Unfortunately again if the error enter /
Inject the voltage on the VS (Voltage on switch) line where there is
a path of 0.75VTT, 1.5VCCORE, 1.05VFGX, 1.2VCCP where this
line only has a maximal 2.5V.jika injection exceeds the maximum
voltage capacity then some components on the line will be
damaged even burned And can cause damage to the circuit
conductor to exacerbate the damage that already exists.